直读光谱仪的常见故障及处理办法「上」
发布时间:2021-06-07
<p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0);"><span style="line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">直读光谱仪常见故障及其相应处理办法由</span><span style="line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: "yes"; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt; mso-ascii-font-family: Calibri; mso-hansi-font-family: Calibri;">莱森光学</span><span style="line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">根据多年的经验总结分享,具体如下:</span></span></p><p style="margin: 0pt; text-align: center; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: "yes"; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt; mso-ascii-font-family: Calibri; mso-hansi-font-family: Calibri;"> <img title="1623036336703480.png" alt="图片1.png" src="/uploads/image/20210607/1623036336703480.png"/></span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">故障一:新仪器电脑出现死机,程序错误、黑屏、分析软件的</span>START<span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">状态不对有时变为黄色不动,有时虽然动但是变为红色。</span></span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">处理办法:此为通讯线接触不良,重新连接即可。</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;"> </span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">故障二:排气不畅故障,氩气排气管路堵塞,火花室下部的弯头内有异物,氩气过滤器入口端有异物。</span> </span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;"> <span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">处理办法:更换排气管,要更换透明的塑料管,并定期对排气管路进行吹扫。</span></span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;"> </span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">故障三:温度偏高故障。</span> </span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">处理办法:检查仪器后盖风扇是否转动,转动是否灵活。</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;"> </span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">故障四:真空泵不自动启动故障。</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: "yes"; mso-fareast-font-family: 宋体; mso-bidi-font-family: "Times New Roman"; mso-font-kerning: 1.0000pt;">处理办法:先看泵油温度是否较低,重新断电后,手动启动真空泵,有时需停顿一下,再试。</span></p><p></p>