服务热线:
86-0755-23229824
您当前所在位置:首页>>光学知识
联系我们

电话:86-0755-23229824

手机:18948346937 / 13510373651

邮箱:info@lisenoptics.com

地址:深圳市宝安区沙井街道后亭茅洲山工业园工业大厦全至科技创新园科创大厦11层C

微信:

立即沟通
直读光谱仪的常见故障及处理办法「上」
<p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0);"><span style="line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">直读光谱仪常见故障及其相应处理办法由</span><span style="line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt; mso-ascii-font-family: Calibri; mso-hansi-font-family: Calibri;">莱森光学</span><span style="line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">根据多年的经验总结分享,具体如下:</span></span></p><p style="margin: 0pt; text-align: center; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt; mso-ascii-font-family: Calibri; mso-hansi-font-family: Calibri;">&nbsp;<img title="1623036336703480.png" alt="图片1.png" src="/uploads/image/20210607/1623036336703480.png"/></span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">故障一:新仪器电脑出现死机,程序错误、黑屏、分析软件的</span>START<span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">状态不对有时变为黄色不动,有时虽然动但是变为红色。</span></span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">处理办法:此为通讯线接触不良,重新连接即可。</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">&nbsp;</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">故障二:排气不畅故障,氩气排气管路堵塞,火花室下部的弯头内有异物,氩气过滤器入口端有异物。</span>&nbsp;</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">&nbsp;<span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">处理办法:更换排气管,要更换透明的塑料管,并定期对排气管路进行吹扫。</span></span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">&nbsp;</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: 宋体; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">故障三:温度偏高故障。</span>&nbsp;</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">处理办法:检查仪器后盖风扇是否转动,转动是否灵活。</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">&nbsp;</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">故障四:真空泵不自动启动故障。</span></p><p style="margin: 0pt; line-height: 1.75em;"><span style="color: rgb(0, 0, 0); line-height: 150%; font-family: Calibri; font-size: 11pt; mso-spacerun: &quot;yes&quot;; mso-fareast-font-family: 宋体; mso-bidi-font-family: &quot;Times New Roman&quot;; mso-font-kerning: 1.0000pt;">处理办法:先看泵油温度是否较低,重新断电后,手动启动真空泵,有时需停顿一下,再试。</span></p><p></p>
Copyright © 2020 All Rights Reserved 莱森光学(深圳) 有限公司·版权所有 备案号:粤ICP备18141551号-1